Impedance Module¶
Impedance calculation module for interfacing with the ERACS Harmonic Impedance engine and running studies. Note that only single point Impedance studies are supported in the Python Interface; trying to set the study type to an Impedance Survey will produce an error. Impedance Surveys can be mimicked in Python by simply running repeated studies across each busbar.
-
class
TEracsImpedance
¶ The low-level ERACS Impedance calculation module. Use this to run Harmonic Impedance studies, or use the TEracsImpedanceEasy class for a simplified approach.
- Inherits
Harmonic.TEracsHarmonic
- This module is dependent on Loadflow.
-
property
VersionNumber
¶ Version number of the calculation module.
- Type
str.
- Writable
False.
-
property
ProgramNumber
¶ Program number of the calculation.
- Type
int.
- Writable
False.
- Example
1 = Loadflow
-
property
NumberOfPoints
¶ Number of points in the Harmonic Impedance study.
- Type
int.
- Writable
False.
-
property
HarmonicValues
¶ Harmonic values as a list.
- Type
list.
- Writable
False.
-
SetupCalculation
(ASetupSimple: Eracs.ImpedanceRecords.THZSetUpData)¶ The second method to call in the Impedance DLL after PassTDFBlock. It passes all required calculation parameters needed to run Harmonic Impedance.
- Parameters
ASetupSimple (THZSetUpData) – Object which contains a record structure holding all of the setup information and is passed to Impedance DLL.
- Raises
TEracsDataError – If the injection bus is not set first.
-
GetResult
(AResultTypeCode, AResultDictionary)¶ Get the next Harmonic Impedance result for a particular element specified by the result typecode.
- Parameters
AResultTypeCode (str) – The typecode of the results, for example: ‘busbar’ or ‘summary’.
AResultDictionary (dict) – This dictionary is populated with the results from the study for the next item.
- Returns
True if the dictionary contains a result (there were more results available).
-
class
TEracsImpedanceEasy
¶ The easy way of running Harmonic Impedance studies. This class contains an instance of TEracsImpedance which it uses to pass in data and extract results. The results can be accessed via properties.
- Inherits
Harmonic.TEracsHarmonicEasy
- All Loadflow-dependent harmonic easy calculation modules should inherit from this class.
-
property
SummaryResults
¶ The summary results for the Harmonic Impedance study.
- Type
dict.
- Writable
False.
-
property
BusbarHarmonicImpedance
¶ The busbar harmonic results for the study.
- Type
- Writable
False.
-
property
BusbarTransferCoefficient
¶ The busbar transfer coefficient results for the study.
- Type
- Writable
False.
-
property
InjectionBus
¶ Injection busbar, one of the Harmonic Impedance setup parameters.
- Type
str.
- Writable
True.
-
property
HarmOff
¶ Harmonic offset, one of the Harmonic Impedance setup parameters.
- Type
int.
- Writable
True.
-
property
HarmMin
¶ Minimum harmonic, one of the Harmonic Impedance setup parameters.
- Type
int.
- Writable
True.
-
property
HarmMax
¶ Maximum harmonic, one of the Harmonic Impedance setup parameters.
- Type
int.
- Writable
True.
-
property
HarmInt
¶ Harmonic intervals, one of the Harmonic Impedance setup parameters.
- Type
int.
- Writable
True.
-
property
NumberOfPoints
¶ Total number of points in the summary results.
- Type
int.
- Writable
False.
-
property
HarmonicValues
¶ List of all harmonic values in the summary results.
- Type
list.
- Writable
False.
-
property
OutputUnits
¶ The output units used for the harmonic values (1 = pu, 2 = Ohms).
- Type
int.
- Writable
True.
-
property
StudyType
¶ Harmonic Impedance study type, surveys are not supported and must be a single point study.
- Type
int.
- Writable
True.
-
ClearResults